What the exam covers

  • Sitework17%
  • Concrete17%
  • Masonry9%
  • Metal Framing6%
  • Carpentry17%
  • Thermal & Moisture Protection12%
  • Doors & Windows7%
  • Finishes9%
  • Safety6%
  • 100 questions, 240 minutes, 70% to pass (PSI).
  • Open book: 2018 International Residential Code and 29 CFR 1926 (OSHA).
  • The same exam qualifies B, B-3 and CR-61.

Source: PSI content outline (B / B-3 / CR-61)

Free sample questions

  1. Presumptive load-bearing value for sandy gravel and gravel (GW, GP) is:

    1. 1,500 psf
    2. 2,000 psf
    3. 3,000 psf
    4. 4,000 psf
    Show answer

    C. 3,000 psf — Rule (2018 IRC Table R401.4.1): sandy gravel and/or gravel (GW and GP) is assigned a presumptive load-bearing value of 3,000 psf. For comparison, clays and silts are 1,500 psf, sands and silty or clayey gravels are 2,000 psf, sedimentary rock 4,000 psf and crystalline bedrock 12,000 psf. Clean, well-graded gravel carries more load because the particles lock together and drain well. 2018 IRC Table R401.4.1 (presumptive load-bearing values) ↗

  2. Sill plate anchor bolts must be embedded in concrete at least:

    1. 4 in
    2. 5 in
    3. 7 in
    4. 10 in
    Show answer

    C. 7 in — Rule (2018 IRC §R403.1.6): anchor bolts must be embedded at least 7 in into concrete or grouted cells of masonry. Bolts are at least 1/2 in in diameter and spaced no more than 6 ft on center, with one within 12 in of each end of every plate section. Embedment is what lets the bolt resist uplift and sliding. 2018 IRC §R403.1.6 (Foundation anchorage) ↗

  3. Masonry veneer ties are spaced no more than how far apart horizontally and vertically?

    1. 16 in
    2. 24 in
    3. 32 in
    4. 48 in
    Show answer

    B. 24 in — Rule (2018 IRC §R703.8.4.1): ties for anchored masonry veneer must be spaced not more than 24 in on center horizontally and vertically, and each tie may support no more than 2.67 sq ft of wall area. In practice, ties on every stud at 16 in o.c. and every 24 in vertically satisfies both limits. 2018 IRC §R703.8.4.1 (Size and spacing) ↗

  4. Cold-formed steel studs used in IRC wall framing must have a minimum protective coating of:

    1. None
    2. G60 galvanizing (or equivalent)
    3. Paint only
    4. Oil
    Show answer

    B. G60 galvanizing (or equivalent) — Rule (2018 IRC §R603.2.2, corrosion protection): load-bearing cold-formed steel framing members must have a metallic coating at least G60 galvanizing (or an equivalent coating such as AZ50 aluminum-zinc). The coating protects the thin steel from rust; members without it, or with damaged coating, must not be used for structural framing. 2018 IRC §R603.2.2 (Corrosion protection) ↗

  5. Splitting a $3,000 job into three $1,000 contracts to stay under the exemption limit is:

    1. Allowed
    2. Not allowed—the exemption doesn't apply to divided contracts or parts of a larger operation
    3. Allowed if the owner agrees
    4. Allowed for repairs only
    Show answer

    B. Not allowed—the exemption doesn't apply to divided contracts or parts of a larger operation — Rule (A.R.S. § 32-1121(A)(14)(b)): the exemption does not apply to work that is part of a larger or major operation, or to a contract that is divided into smaller amounts to stay under the $1,000 limit. Three $1,000 contracts for one $3,000 job require a license. A.R.S. §32-1121 (Persons not required to be licensed) ↗

Questions people ask

What is on the Arizona B exam?

It is weighted by section: Sitework 17%, Concrete 17%, Masonry 9%, Metal Framing 6%, Carpentry 17%, Thermal & Moisture Protection 12%, Doors & Windows 7%, Finishes 9%, Safety 6%.

What is the B exam format?

100 questions, 240 minutes, 70% to pass (PSI). Open book: 2018 International Residential Code and 29 CFR 1926 (OSHA). The same exam qualifies B, B-3 and CR-61.

Are these the real exam questions?

No. Licensing boards keep their exams confidential. Our questions are written from the official exam outlines, study guides and code books, and each answer links to its source.

Is there a free trial?

Yes. Every new account gets 3 days of full access to every exam, with no card needed.

Independent study tool, not affiliated with AZ ROC. How our questions are made.