All states / Arizona / B-1
Arizona B-1 General Commercial (also B-2, KB-1, KB-2) practice test
606 practice questions (B-1 trade + Statutes & Rules), with full mock exams weighted like the real AZ ROC exam, explanations with sources, and a readiness score.
What the exam covers
- Sitework9%
- Concrete14%
- Masonry10%
- Metals13%
- Carpentry12%
- Thermal & Moisture Protection10%
- Doors & Windows5%
- Finishes6%
- Safety12%
- General Building Code9%
- 100 questions, 240 minutes, 70% to pass (PSI).
- Open book: 2018 IBC, 2018 IRC and 29 CFR 1926.
- The same exam qualifies B-1, B-2, KB-1 and KB-2 (B-1/B-2 may also use the NASCLA exam).
Free sample questions
Presumptive load-bearing value for sandy gravel and gravel (GW, GP) is:
- 1,500 psf
- 2,000 psf
- 3,000 psf
- 4,000 psf
Show answer
C. 3,000 psf — Rule (2018 IRC Table R401.4.1): sandy gravel and/or gravel (GW and GP) is assigned a presumptive load-bearing value of 3,000 psf. For comparison, clays and silts are 1,500 psf, sands and silty or clayey gravels are 2,000 psf, sedimentary rock 4,000 psf and crystalline bedrock 12,000 psf. Clean, well-graded gravel carries more load because the particles lock together and drain well. 2018 IRC Table R401.4.1 (presumptive load-bearing values) ↗
Sill plate anchor bolts must be embedded in concrete at least:
- 4 in
- 5 in
- 7 in
- 10 in
Show answer
C. 7 in — Rule (2018 IRC §R403.1.6): anchor bolts must be embedded at least 7 in into concrete or grouted cells of masonry. Bolts are at least 1/2 in in diameter and spaced no more than 6 ft on center, with one within 12 in of each end of every plate section. Embedment is what lets the bolt resist uplift and sliding. 2018 IRC §R403.1.6 (Foundation anchorage) ↗
Masonry walls over 8 ft high must be:
- Unbraced
- Adequately braced to prevent overturning until permanently supported
- Painted
- Grouted only
Show answer
B. Adequately braced to prevent overturning until permanently supported — Rule (OSHA 29 CFR 1926.706(b)): all masonry walls over 8 ft in height must be adequately braced to prevent overturning and to prevent collapse unless the wall is adequately supported so that it will not overturn or collapse. The bracing must remain in place until permanent supporting elements of the structure are in place. Fresh masonry walls have little strength against wind. OSHA 29 CFR 1926.706(b) (Masonry construction) ↗
Screws in cold-formed steel framing must extend through the steel at least:
- 1 thread
- 3 exposed threads
- 1 in
- Flush
Show answer
B. 3 exposed threads — Rule (2018 IRC §R804.2.5, fastening requirements; the wall-framing section has the same requirement): screws for steel-to-steel connections must be installed with a minimum edge distance and center-to-center spacing of 1/2 in, be self-drilling tapping, and extend through the steel with at least three exposed threads. Three exposed threads show that the screw fully engaged all layers of steel. 2018 IRC §R804.2.5 (Fastening requirements) ↗
Splitting a $3,000 job into three $1,000 contracts to stay under the exemption limit is:
- Allowed
- Not allowed—the exemption doesn't apply to divided contracts or parts of a larger operation
- Allowed if the owner agrees
- Allowed for repairs only
Show answer
B. Not allowed—the exemption doesn't apply to divided contracts or parts of a larger operation — Rule (A.R.S. § 32-1121(A)(14)(b)): the exemption does not apply to work that is part of a larger or major operation, or to a contract that is divided into smaller amounts to stay under the $1,000 limit. Three $1,000 contracts for one $3,000 job require a license. A.R.S. §32-1121 (Persons not required to be licensed) ↗
Questions people ask
What is on the Arizona B-1 exam?
It is weighted by section: Sitework 9%, Concrete 14%, Masonry 10%, Metals 13%, Carpentry 12%, Thermal & Moisture Protection 10%, Doors & Windows 5%, Finishes 6%, Safety 12%, General Building Code 9%.
What is the B-1 exam format?
100 questions, 240 minutes, 70% to pass (PSI). Open book: 2018 IBC, 2018 IRC and 29 CFR 1926. The same exam qualifies B-1, B-2, KB-1 and KB-2 (B-1/B-2 may also use the NASCLA exam).
Are these the real exam questions?
No. Licensing boards keep their exams confidential. Our questions are written from the official exam outlines, study guides and code books, and each answer links to its source.
Is there a free trial?
Yes. Every new account gets 3 days of full access to every exam, with no card needed.
Independent study tool, not affiliated with AZ ROC. How our questions are made.