How to pass the Arizona B-1 General Commercial exam

A study guide for the Arizona B-1 General Commercial exam: what it covers, how much each section counts, the rules that come up most, and a study plan. Rules below link to their official source wherever one exists.

The exam at a glance

  • 100 questions, 240 minutes, 70% to pass (PSI).
  • Open book: 2018 IBC, 2018 IRC and 29 CFR 1926.
  • The same exam qualifies B-1, B-2, KB-1 and KB-2 (B-1/B-2 may also use the NASCLA exam).

Source: PSI content outline (B-1 / B-2 / KB-1 / KB-2). Always confirm details with AZ ROC before test day.

What's on the exam

  • Concrete14%
  • Metals13%
  • Carpentry12%
  • Safety12%
  • Masonry10%
  • Thermal & Moisture Protection10%
  • Sitework9%
  • General Building Code9%
  • Finishes6%
  • Doors & Windows5%

Section weights from the official exam outline. Bigger sections are worth more points, so study them first.

A 4-step study plan

  1. Take a baseline test. Answer a full mock exam before studying so you know where you stand in each section.
  2. Study by weight, then by weakness. Start with Concrete (14%), Metals (13%), Carpentry (12%), then move to whichever sections scored lowest on your baseline.
  3. Learn the rule, not just the answer. For every miss, read the explanation and the code section or statute it cites; on test day you'll need to know these references well.
  4. Repeat mock exams until you're consistently at 80% or more, which gives you a cushion above the passing score. Retake the questions you missed until they stick.

Key rules to know, by section

A few of the facts that come up in each section, with the answer and the source. The full course has 606 questions with explanations.

Concrete 14% of the exam · 37 practice questions

  • Footings must be placed at least how far below undisturbed ground (2018 IRC)? 12 in. Rule (2018 IRC §R403.1.4): exterior footings must be placed at least 12 in below the undisturbed ground surface. Where frost applies, the footing must also go below the frost depth set in Table R301.2(1) (R403.1.4.1). 2018 IRC §R403.1.4 (Minimum depth) ↗
  • Control joints in a slab are cut to a depth of about? 1/4 of thickness. Control (contraction) joints are cut or tooled to about one-quarter of the slab thickness (for example, 1 in deep in a 4 in slab). This creates a weakened plane so that shrinkage cracks form in a straight line at the joint instead of randomly across the slab.
  • Concrete cover for primary reinforcement in cast-in-place beams and columns not exposed to weather or in contact with ground is? 1-1/2 in. Rule (ACI 318, Table 20.6.1.3.1): for cast-in-place nonprestressed concrete not exposed to weather or in contact with ground, beams and columns require 1-1/2 in of cover to the primary reinforcement, ties, stirrups and spirals.

Metals 13% of the exam · 23 practice questions

  • When steel framing contacts dissimilar metals like copper, you should? Isolate them to prevent galvanic corrosion. When two different metals touch in the presence of moisture (an electrolyte), the less noble metal corrodes. Galvanized steel framing in contact with copper pipe will corrode quickly.
  • Metal roof and floor deck is typically attached to steel framing with? Puddle welds or mechanical fasteners, plus side-lap fasteners. Metal roof and floor deck is attached to supporting steel by arc puddle welds (arc spot welds) or by mechanical fasteners such as powder-actuated pins or screws, at the pattern shown in the deck design.

Carpentry 12% of the exam · 39 practice questions

  • Required guards on open-sided walking surfaces in a dwelling must be at least (2018 IRC)? 36 in. Rule (2018 IRC §R312.1.2): required guards at open-sided walking surfaces, including stairs, ramps and landings, must be at least 36 in high, measured vertically above the adjacent walking surface. 2018 IRC §R312.1.2 (Guard height) ↗
  • End joints in a double top plate must be offset at least? 24 in. Rule (2018 IRC §R602.3.2): wood stud walls must be capped with a double top plate, installed to provide overlapping at corners and intersections with bearing partitions. End joints in the top plates must be offset at least 24 in. 2018 IRC §R602.3.2 (Top plate) ↗
  • What is the actual size of a 2×4? 1-1/2 × 3-1/2 in. Nominal lumber sizes are the rough-sawn size before drying and planing (surfacing). A nominal 2×4 is actually 1-1/2 × 3-1/2 in. The rule of thumb: nominal 2, 4 and 6 in dimensions lose 1/2 in; nominal 8 in and wider lose 3/4 in.

Safety 12% of the exam · 33 practice questions

  • Protective systems for trenches deeper than how much must be designed by a registered professional engineer? 20 ft. Rule (OSHA 29 CFR 1926.652(b) and (c)): sloping and benching systems, and support or shield systems, for excavations greater than 20 ft deep must be designed by a registered professional engineer. OSHA 29 CFR 1926.652 (Requirements for protective systems) ↗
  • Hard hats are required where there is a danger of? Head injury from impact, falling objects or electrical shock. Rule (OSHA 29 CFR 1926.100(a)): employees working in areas where there is a possible danger of head injury from impact, falling or flying objects, or electrical shock and burns must be protected by protective helmets (hard hats). OSHA 29 CFR 1926.100 (Head protection) ↗
  • A competent person is someone who can identify hazards and? Has authority to take prompt corrective measures. Rule (OSHA 29 CFR 1926.32(f)): a 'competent person' is one who is capable of identifying existing and predictable hazards in the surroundings or working conditions that are unsanitary, hazardous or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them. OSHA 29 CFR 1926.32(f) (Definitions) ↗

Masonry 10% of the exam · 22 practice questions

  • Type N mortar is typically used for? General above-grade exterior and interior walls. Type N mortar is a medium-strength, general-purpose mortar for above-grade exterior and interior walls (including veneer) that are not heavily loaded.
  • Masonry walls over 8 ft high must be? Adequately braced to prevent overturning until permanently supported. Rule (OSHA 29 CFR 1926.706(b)): all masonry walls over 8 ft in height must be adequately braced to prevent overturning and to prevent collapse unless the wall is adequately supported so that it will not overturn or collapse. OSHA 29 CFR 1926.706(b) (Masonry construction) ↗
  • Running bond means? Each course offset by half a unit. Running bond (half bond) offsets each course by half a unit, so head joints in alternate courses line up and the units interlock. This spreads loads and resists cracking.

Thermal & Moisture Protection 10% of the exam · 25 practice questions

  • Drip edge pieces must overlap at least? 2 in. Rule (2018 IRC §R905.2.8.5): adjacent pieces of drip edge must overlap at least 2 in. 2018 IRC §R905.2.8.5 (Drip edge) ↗
  • A higher R-value insulation means? More resistance to heat flow. R-value measures thermal resistance, how well a material resists conductive heat flow. A higher R-value means more resistance and better insulation. R-values of layers in series add together (R-13 cavity insulation plus R-5 continuous insulation = R-18).
  • A new roof covering may not be installed over existing roofing when there are already? Two or more layers. Rule (2018 IRC §R908.3.1.1): a roof recover (installing new roofing over existing roofing) is not allowed where the existing roof or roof covering is water-soaked or deteriorated so it is not an adequate base, where the existing covering is slate, clay, cement or asbestos-cement tile, or wood shakes, or where the existing roof has two or more applications of any type of roof covering. 2018 IRC §R908.3.1.1 (Roof recover not allowed) ↗

Sitework 9% of the exam · 22 practice questions

  • Batter boards are used to? Hold string lines marking the building outside the excavation. Batter boards are horizontal boards set on stakes a few feet outside the building corners. String lines stretched between them mark the exact building lines and can be removed and replaced.
  • Footing excavations should be inspected? Before concrete is placed. Rule (2018 IRC §R109.1.1): the foundation inspection is made after trenches are excavated and forms are erected, and when all materials for the foundation are delivered on the job, but before any concrete is placed. 2018 IRC §R109.1.1 (Foundation inspection) ↗
  • Fill under footings and slabs should be? Placed in thin lifts and compacted to the specified density. Fill under footings and slabs must be placed in thin lifts (commonly 6 to 8 in) and each lift compacted to the specified density, usually a percentage of maximum density from a Proctor test, before the next lift goes on.

General Building Code 9% of the exam · 45 practice questions

  • Apartments are IBC occupancy Group? R-2. Rule (2018 IBC §310.3): Residential Group R-2 contains sleeping units or more than two dwelling units where the occupants are primarily permanent (nontransient) in nature. 2018 IBC §310.3 (Residential Group R-2) ↗
  • Minimum clear width of egress doors (IBC)? 32 in. Rule (2018 IBC §1010.1.1): means of egress doors must provide a clear width of at least 32 in, measured between the face of the door and the stop with the door open 90 degrees. The maximum width of a swinging door leaf is 48 in nominal. 2018 IBC §1010.1.1 (Size of doors) ↗
  • Uniform live load for lobbies and first-floor corridors (IBC Table 1607.1)? 100 psf. Rule (2018 IBC §1607.1, Table 1607.1): lobbies and first-floor corridors in office buildings are designed for a uniform live load of 100 psf, because crowds gather there. Corridors above the first floor are 80 psf, and office areas themselves 50 psf. 2018 IBC Table 1607.1 (minimum live loads) ↗

Finishes 6% of the exam · 19 practice questions

  • Shower and tub walls need a nonabsorbent surface to a height of at least how far above the floor? 72 in. Rule (2018 IRC §R307.2): bathtub and shower floors, walls above bathtubs with installed showerheads, and walls in shower compartments must be finished with a nonabsorbent surface. 2018 IRC §R307.2 (Bathtub and shower spaces) ↗
  • Suspended acoustical ceiling grids are typically hung with hanger wires spaced at no more than? 4 ft. Rule (ASTM C636, installation of suspended ceiling systems): hanger wires for suspended acoustical ceiling grids are typically spaced at no more than 4 ft on center along main runners, with additional hangers within a short distance of the ends of runners and at fixtures.
  • Drywall screws should be driven? Just below the surface without breaking the face paper. Drywall screws should be driven just below the surface, creating a shallow dimple, without breaking or tearing the face paper. The dimple holds joint compound so the fastener can be concealed.

Doors & Windows 5% of the exam · 19 practice questions

  • A window well for a below-grade escape window needs a ladder or steps when it is deeper than? 44 in. Rule (2018 IRC §R310.2.3.1): window wells with a vertical depth greater than 44 in must be equipped with a permanently affixed ladder or steps usable with the window in the fully open position. 2018 IRC §R310.2.3.1 (Ladder and steps) ↗
  • Storefront and curtain wall glazing within 24 in of a door must be? Safety glazing. Rule (2018 IBC §2406.4): glazing in hazardous locations requires safety glazing. 2018 IBC §2406.4 (Hazardous glazing locations) ↗
  • Glazing adjacent to a door is a hazardous location requiring safety glazing when it is within a 24 in arc of the door and its bottom edge is less than? 60 in above the floor. Rule (2018 IRC §R308.4.2): glazing is a hazardous location requiring safety glazing when it is in a fixed or operable panel adjacent to a door, the nearest vertical edge is within a 24 in arc of either vertical edge of the door in the closed position, and the bottom exposed edge of the glazing is less than 60 in above the floor or walking surface. 2018 IRC §R308.4.2 (Glazing adjacent to doors) ↗

The Statutes & Rules exam

Most Arizona applicants also take the Statutes & Rules exam. Its sections:

  • Licensing & Classifications20%
  • Contracts, Advertising & Payment20%
  • Qualifying Party & License Upkeep15%
  • Bonds & Recovery Fund15%
  • Mechanics' Liens15%
  • Complaints & Penalties15%

Licensing & Classifications 20% of the exam · 137 practice questions

  • An owner may build or improve their own property without a license if the structure is? Intended solely for the owner's occupancy, not for sale or rent. Rule (A.R.S. § 32-1121(A)(5)): owners may build or improve structures on their own property without a license only if the work is intended solely for their own occupancy and not offered for sale or rent. A.R.S. §32-1121 (Persons not required to be licensed) ↗
  • The B-3 General Remodeling and Repair license covers? Remodeling and repair of existing residential structures. Rule (A.A.C. R4-9-103, B-3 General Remodeling and Repair): the B-3 license covers remodeling and repair of existing residential structures, including the R-7 carpentry scope. Other trades such as electrical and plumbing must be subcontracted. A.A.C. R4-9-103 (B-3 General Remodeling and Repair), ROC rules p. 11 ↗

Contracts, Advertising & Payment 20% of the exam · 36 practice questions

  • Under the Arizona Prompt Pay Act, an owner has how long to approve or object to a progress billing? 14 days. Rule (Arizona Prompt Pay Act, A.R.S. § 32-1182): an owner has 14 days after receiving a progress billing to certify and approve it, or to object in writing. A.R.S. §32-1182 (Progress payments by owner) ↗
  • An unlicensed person advertises 'Kitchen remodels — call us!' without the required statement. This violates? Arizona's advertising rules and the consumer fraud act (A.R.S. § 44-1522). Rule (A.R.S. § 32-1121(C) and § 44-1522): an unlicensed person who advertises for work that requires a license, or omits the required 'not a licensed contractor' statement, violates Arizona's advertising rules and commits consumer fraud. A.R.S. §32-1121 (Persons not required to be licensed) ↗

Qualifying Party & License Upkeep 15% of the exam · 51 practice questions

  • If the licensee does not replace its qualifying party in time, the license is? Automatically suspended by operation of law. Rule (A.R.S. § 32-1127.01(C)): if the licensee doesn't replace its qualifying party within the 60-day period, the license is automatically suspended by operation of law until a qualified replacement is approved. A.R.S. §32-1127.01 (Qualifying party disassociation) ↗
  • Reactivating an inactive license requires? The renewal fee and 30 days' written notice. Rule (A.R.S. § 32-1125.01): to reactivate an inactive license, the licensee gives the registrar 30 days' written notice and pays the renewal fee. No new exam is required. A.R.S. §32-1125.01 (Inactive license) ↗

Bonds & Recovery Fund 15% of the exam · 38 practice questions

  • Residential and dual licensees must either join the Residential Contractors' Recovery Fund or post an additional bond of? $200,000. Rule (A.R.S. § 32-1152): residential and dual licensees must either participate in the Residential Contractors' Recovery Fund or post an additional bond of $200,000. A.R.S. §32-1152 (Bonds) ↗
  • Recovery Fund actual damages are the reasonable cost to complete the contract and repair defective work? Minus the unpaid contract price. Rule (A.R.S. § 32-1132.01(H)): Recovery Fund actual damages are the reasonable cost to complete the contract and repair defective work, minus any unpaid contract price the owner still owes. A.R.S. §32-1132.01 (Recovery fund damages and limits) ↗

Mechanics' Liens 15% of the exam · 29 practice questions

  • If the owner records and serves a notice of completion, a lien must be recorded within? 60 days after the notice. Rule (A.R.S. § 33-993(A)): if the owner records and serves a notice of completion, a lien must be recorded within 60 days after the notice is recorded. A.R.S. §33-993 (Perfecting a lien) ↗
  • A preliminary notice includes an estimate of? The total price of labor and materials to be furnished. Rule (A.R.S. § 33-992.01): a preliminary notice must include an estimate of the total price of the labor, materials and equipment the claimant will furnish. A.R.S. §33-992.01 (Preliminary twenty-day notice) ↗

Complaints & Penalties 15% of the exam · 31 practice questions

  • The maximum civil penalty for multiple violations committed on the same day is? $2,500. Rule (A.R.S. § 32-1166.01): the Registrar may issue citations with civil penalties to persons who contract without a license. The total civil penalty for all violations committed on the same day may not exceed $2,500. A.R.S. §32-1166.01 (Citations; civil penalties) ↗
  • A homeowner who hires an unlicensed contractor generally? Cannot claim from the Recovery Fund. Rule (A.R.S. § 32-1132): the Recovery Fund covers only damage caused by appropriately licensed residential contractors, so a homeowner who hires an unlicensed contractor generally can't claim from it. A.R.S. §32-1132 (Residential contractors' recovery fund) ↗

Questions people ask

What is on the Arizona B-1 General Commercial exam?

The exam is weighted by section: Concrete 14%, Metals 13%, Carpentry 12%, Safety 12%, Masonry 10%, Thermal & Moisture Protection 10%, Sitework 9%, General Building Code 9%, Finishes 6%, Doors & Windows 5%.

What is the format of the Arizona B-1 General Commercial exam?

100 questions, 240 minutes, 70% to pass (PSI). Open book: 2018 IBC, 2018 IRC and 29 CFR 1926. The same exam qualifies B-1, B-2, KB-1 and KB-2 (B-1/B-2 may also use the NASCLA exam).

What should I study first for the Arizona B-1 General Commercial exam?

Start with the largest sections, which carry the most points: Concrete (14%), Metals (13%), Carpentry (12%). Then take a timed mock exam and spend extra time on whatever scored lowest.

Do I also need the Statutes & Rules exam?

Most applicants for this license also take the Statutes & Rules exam. It is included with this course, so you can practice both.

Where can I practice for the Arizona B-1 General Commercial exam?

LicenseExamReady has 606 practice questions for the Arizona B-1 General Commercial exam and the Statutes & Rules exam, full mock exams weighted like the real test, explanations that cite the code section or rule, and a readiness score. New accounts get a free 3-day trial.

Are practice questions the same as the real exam?

No. Licensing boards keep their exams confidential. Good practice questions are written from the official exam outline and code books and teach the rule behind each answer.

Practice for the Arizona B-1 General Commercial exam

606 practice questions, full-length timed mock exams weighted like the real test, explanations with sources, and a readiness score that shows when you're ready to book the exam.

LicenseExamReady is an independent study tool, not affiliated with Arizona Registrar of Contractors. How our questions are made.