Arizona R-11 Electrical (Residential) practice test

478 practice questions (R-11 trade + Statutes & Rules), with full mock exams weighted like the real AZ ROC exam, explanations with sources, and a readiness score.

What the exam covers

  • General Electrical Knowledge5%
  • Services, Feeders & Branch Circuits16%
  • Grounding & Bonding15%
  • Conductors & Cables11%
  • Raceways & Boxes14%
  • Special Occupancies & Equipment3%
  • Electrical Devices2%
  • Motors3%
  • Low Voltage2%
  • Lighting5%
  • Fire Detection & Alarm5%
  • Safety5%
  • Overcurrent Protection6%
  • Photovoltaics9%
  • 110 questions, 240 minutes, 70% to pass (PSI).
  • Open book: 2017 NEC, NFPA 72 (2016) and 29 CFR 1926.

Source: PSI content outline (R-11)

Free sample questions

  1. Power factor is the ratio of:

    1. Volts to amps
    2. Real power (W) to apparent power (VA)
    3. Ohms to watts
    4. kW to hp
    Show answer

    B. Real power (W) to apparent power (VA) — Power factor (PF) = real power (watts) ÷ apparent power (volt-amperes), a number between 0 and 1. Resistive loads have a PF of 1. Inductive loads such as motors and transformers have a PF below 1, so they draw more current than their wattage suggests. Example: a load drawing 1,000 VA at a PF of 0.8 uses 800 W of real power. (Standard trade practice — not set by a specific code section)

  2. Kitchen countertop receptacles are placed so no point along the wall line is more than how far from one?

    1. 12 in
    2. 24 in
    3. 36 in
    4. 48 in
    Show answer

    B. 24 in — Rule (NEC 2017 §210.52(C)(1)): in kitchens and similar areas, a receptacle outlet must be installed at each wall countertop space 12 in or wider, and receptacles must be installed so that no point along the wall line is more than 24 in, measured horizontally, from a receptacle outlet in that space. With a 24 in maximum to each side, countertop receptacles can be up to 48 in apart, so small appliance cords (typically about 2 ft) reach without extension cords. NEC 2017 §210.52(C)(1) (countertop receptacles) — free NFPA account to read ↗

  3. A ground ring electrode must be at least:

    1. 8 ft of 6 AWG
    2. 20 ft of bare copper not smaller than 2 AWG
    3. 10 ft of 4 AWG
    4. Any size
    Show answer

    B. 20 ft of bare copper not smaller than 2 AWG — Rule (NEC 2017 §250.52(A)(4) and §250.53(F)): a ground ring electrode encircles the building, in direct contact with the earth, and consists of at least 20 ft of bare copper conductor not smaller than 2 AWG. It must be buried at a depth below the earth's surface of not less than 30 in. The grounding electrode conductor to it need not be larger than the ring conductor (§250.66(C)). NEC 2017 §250.52(A)(4) (ground ring) — free NFPA account to read ↗

  4. Residential 120 V, 20 A or less GFCI-protected circuits may be buried at a cover of:

    1. 6 in
    2. 12 in
    3. 18 in
    4. 24 in
    Show answer

    B. 12 in — Rule (NEC 2017 §300.5, Table 300.5, Column 4): residential branch circuits rated 120 V or less with GFCI protection and maximum overcurrent protection of 20 A require only 12 in of cover. The GFCI reduces the shock risk if a shovel cuts the cable. Without GFCI, direct-buried cable needs 24 in and PVC 18 in. NEC 2017 Table 300.5 (minimum cover) — free NFPA account to read ↗

  5. Splitting a $3,000 job into three $1,000 contracts to stay under the exemption limit is:

    1. Allowed
    2. Not allowed—the exemption doesn't apply to divided contracts or parts of a larger operation
    3. Allowed if the owner agrees
    4. Allowed for repairs only
    Show answer

    B. Not allowed—the exemption doesn't apply to divided contracts or parts of a larger operation — Rule (A.R.S. § 32-1121(A)(14)(b)): the exemption does not apply to work that is part of a larger or major operation, or to a contract that is divided into smaller amounts to stay under the $1,000 limit. Three $1,000 contracts for one $3,000 job require a license. A.R.S. §32-1121 (Persons not required to be licensed) ↗

Questions people ask

What is on the Arizona R-11 exam?

It is weighted by section: General Electrical Knowledge 5%, Services, Feeders & Branch Circuits 16%, Grounding & Bonding 15%, Conductors & Cables 11%, Raceways & Boxes 14%, Special Occupancies & Equipment 3%, Electrical Devices 2%, Motors 3%, Low Voltage 2%, Lighting 5%, Fire Detection & Alarm 5%, Safety 5%, Overcurrent Protection 6%, Photovoltaics 9%.

What is the R-11 exam format?

110 questions, 240 minutes, 70% to pass (PSI). Open book: 2017 NEC, NFPA 72 (2016) and 29 CFR 1926.

Are these the real exam questions?

No. Licensing boards keep their exams confidential. Our questions are written from the official exam outlines, study guides and code books, and each answer links to its source.

Is there a free trial?

Yes. Every new account gets 3 days of full access to every exam, with no card needed.

Independent study tool, not affiliated with AZ ROC. How our questions are made.